{"id":16655,"date":"2025-02-04T13:25:51","date_gmt":"2025-02-04T11:25:51","guid":{"rendered":"http:\/\/flameguard.ee.dedi7782.your-server.de\/?post_type=product&#038;p=16655"},"modified":"2025-03-08T19:53:50","modified_gmt":"2025-03-08T17:53:50","slug":"kohaliku-omavalitsuse-sisekoolitused","status":"publish","type":"product","link":"https:\/\/flameguard.ee\/en\/product\/local-government-internal-training\/","title":{"rendered":"Internal training of local governments"},"content":{"rendered":"<p><span data-contrast=\"auto\">The following topics can be addressed during the course of the training:<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}\">\u00a0<\/span><\/p>\n<p><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}\">\u00a0<\/span><b><span data-contrast=\"auto\">Assessment of fire hazard risks<\/span><\/b><br \/>\n<span data-contrast=\"auto\">1. Assessment of fire safety risks in the area.<\/span><br \/>\n<span data-contrast=\"auto\">2. Assessment of fire safety risks in buildings and territories.<\/span><\/p>\n<p><b><span data-contrast=\"auto\">Assessment of structural fire safety<\/span><\/b><br \/>\n<span data-contrast=\"auto\">1. Assessment of conformity of construction works, parts of construction works or building design documentation with fire safety requirements.<\/span><br \/>\n<span data-contrast=\"auto\">2. Assessment of conformity of fire safety installations.<\/span><br \/>\n<span data-contrast=\"auto\">3. Assessment of conformity of products with fire safety requirements.<\/span><br \/>\n<span data-contrast=\"auto\">4. Assessment of fire safety requirements for services.<\/span><br \/>\n<span data-contrast=\"auto\">5. Preparation of assessment.<\/span><br \/>\n<span data-contrast=\"auto\">6. Providing consultation services in the field of fire safety.<\/span><\/p>\n<p><b><span data-contrast=\"auto\">Assessment of organisational fire safety<\/span><\/b><br \/>\n<span data-contrast=\"auto\">1. Assessment of the proper use of the terrestrial\/build\/space, installation and equipment.<\/span><br \/>\n<span data-contrast=\"auto\">2. Assessment of fire safety organisation of construction works, institutions or enterprises.<\/span><br \/>\n<span data-contrast=\"auto\">3. Preparation of assessment.<\/span><br \/>\n<span data-contrast=\"auto\">4. Preparation\/updating of documentation.<\/span><\/p>\n<p><b><span data-contrast=\"auto\">Information and consultancy relating to fire safety<\/span><\/b><br \/>\n<span data-contrast=\"auto\">1. Notification of fire safety requirements.<\/span><br \/>\n<span data-contrast=\"auto\">2. Consultancy in the field of fire safety.<\/span><\/p>\n<p><b><span data-contrast=\"auto\">Conduct of expert assessment and audit of special part of fire safety<\/span><\/b><br \/>\n<span data-contrast=\"auto\">1. Conduct of expert assessment of special part of fire safety of building design documentation.<\/span><br \/>\n<span data-contrast=\"auto\">2. Performance of fire safety audit of construction works.<\/span><br \/>\n<span data-contrast=\"auto\">3. Selection and involvement of experts\/specialists.<\/span><br \/>\n<span data-contrast=\"auto\">4. Evaluation of available data, application for additional material and studies.<\/span><br \/>\n<span data-contrast=\"auto\">5. Coordination of the work process.<\/span><br \/>\n<span data-contrast=\"auto\">6. Analyzing data.<\/span><br \/>\n<span data-contrast=\"auto\">7. Preparation of a summary expert\/audit report.<\/span><br \/>\n<span data-contrast=\"auto\">8. Development of structural fire safety solutions for buildings or parts thereof.<\/span><br \/>\n<span data-contrast=\"auto\">9. Presentation and protection of expert\/audit reports.<\/span><br \/>\n<span data-contrast=\"auto\">10. Fire safety expert level 6 qualifications and co-operation opportunities<\/span><\/p>\n<p><b><span data-contrast=\"auto\">List of standards related to the fire safety part of the building design that can be addressed during training\u00a0<\/span><\/b><\/p>\n<ol>\n<li><span data-contrast=\"auto\">EVS 812-2:2014 + AC:2017 \u2013 fire safety of buildings. Part 2: ventilation systems<\/span><\/li>\n<li><span data-contrast=\"auto\">EVS 812-3:2018 \u2013 fire safety of buildings. Part 3: heating systems<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS 812-4:2018 \u2013 fire safety of buildings. Part 4: fire safety of industrial and storage buildings and garages<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS 812-5:2014 \u2013 fire safety of buildings. Part 5: fire safety of fuel terminals and service stations<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS 812-6:2012 + A1: 2013 + AC:2016 + A2: 2017 \u2013 fire safety of buildings. Part 6: Tulet\u00f5rje veevarustus<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS 812-7:2018 \u2013 fire safety of buildings. Part 7: fire safety requirements for buildings<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS 812-8:2018 \u2013 fire safety of buildings. Part 8: fire safety of high-rise buildings<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS 871:2017 \u2013 opening fillings and feathers for fire protection and evacuation<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS-EN 1838:2013 \u2014 Emergency lighting for lighting equipment<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS-EN 50172:2005 \u2014 escape emergency lighting systems<\/span><\/li>\n<li><span data-contrast=\"auto\"> CEN\/TS 54-14:2004 \u2014 Automatic fire detection system: planning, design, installation, inspection, operation and maintenance rules<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS-EN 12845:2015 \u2013 fixed fire fighting systems. Automatic sprinkler systems. Design, installation and maintenance.<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS-EN 15004-1:2008 \u2014 fixed fire fighting systems. Gas extinguishing systems: design, <\/span><span data-contrast=\"auto\">installation and maintenance<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS-EN 62305-1:2011 + AC:2016 \u2013 lightning protection. Part 1: General principles<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS-EN 62305-2:2013 \u2014 lightning protection. Part 2: risk analysis<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS-EN 62305-3:2011 \u2014 lightning protection. Part 3: physical damage to buildings and danger to life<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS-EN 62305-4:2011 + AC:2016 \u2014 Electrical and electronic systems for buildings<\/span><\/li>\n<li><span data-contrast=\"auto\"> EVS 919:2013 + A1: 2014 - smoke control. Design, installation and maintenance of apparatus<\/span><\/li>\n<\/ol>\n<p><span data-contrast=\"auto\">OKAY! When reading and interpreting a building design documentation, the validity of a particular standard must be checked from the Centre for Standardisation (www.evs.ee).<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}\">\u00a0<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p><span data-contrast=\"auto\">The training introduces fire safety requirements for local government specialists for building projects and explains how the safety of buildings must be ensured in accordance with the applicable laws and standards.\u00a0<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:0,&quot;335559740&quot;:240}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">As of 01.03.2021, only fire safety experts with professional certificates (level 5) or fire safety experts (level<\/span><\/b><span data-contrast=\"auto\"> 6) who also has the relevant competence to conduct training. We recommend checking the trainer background <\/span><span style=\"color: #ff6600;\"><a style=\"color: #ff6600;\" href=\"http:\/\/www.kutsekoda.ee\/\">www.kutsekoda.ee<\/a>\u00a0<\/span><\/p>\n<p>Training can be ordered in Estonian, English and Russian.<\/p>\n<p><strong>If questions arise and you wish to receive personal group training, please contact us.\u00a0\u00a0<\/strong><\/p>\n<p>&nbsp;<\/p>","protected":false},"featured_media":18373,"template":"","meta":[],"product_brand":[],"product_cat":[122,121,124,120,116,119,118],"product_tag":[],"class_list":{"0":"post-16655","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-auditeerimine","7":"product_cat-keskkonnajuhtimine","8":"product_cat-koolitamine","9":"product_cat-kvaliteedijuhtimine","10":"product_cat-teenused","11":"product_cat-tooohutus-ja-tervishoid","12":"product_cat-tuleohutus","14":"first","15":"instock","16":"virtual","17":"taxable","18":"purchasable","19":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/product\/16655","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":11,"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/product\/16655\/revisions"}],"predecessor-version":[{"id":18409,"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/product\/16655\/revisions\/18409"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/media\/18373"}],"wp:attachment":[{"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/media?parent=16655"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/product_brand?post=16655"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/product_cat?post=16655"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/flameguard.ee\/en\/wp-json\/wp\/v2\/product_tag?post=16655"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}