Fire safety audit

90.00
We carry out fire safety audits on individual homes, auxiliary buildings, apartment buildings, as well as industrial, office and assembly buildings. Fire safety audit begins by examining the fire safety documentation of the construction work and is followed by an inspection of the object. The state and structures of fire safety installations shall also be checked during the inspection. As a result, a fire safety audit will be completed. If fire safety deficiencies occur, we will advise on their elimination. In addition, if necessary, we can provide assistance in remedying the identified shortcomings.
Expert assessment should only be carried out on a valid basis fire safety expert level 6 a person with professional qualifications.

Expert assessment of heating systems

90.00
Expert assessments or audits of heating systems are usually required for two reasons. First, it provides the owner of the building with the necessary information on the safety of the use of fireplaces and explains whether a modification or repair of the heating system is necessary. Secondly, the expert assessment of the heating system is one of the many documents needed in the application process. Expert assessment of heating systems and heating fireplaces usually involves first checking of heating equipment and assessing the integrity thereof. In addition, the following aspects are also important:
  • inspection of stacks;
  • inspection of connecting flues;
  • assessment of the conformity of the heating system with building requirements, including fire safety requirements;
  • integrity of fire compartments;
  • review of existing documentation of heating system.
Expert assessment should only be carried out on a valid basis chimney sweeper-master level 5, potter Master level 5, fire safety expert level 6  a person with professional qualifications.

FIPRON cord 3 fire-extinguishing cord

384.30
FIPRON ™ ord 3 is a string type stand-alone fire extinguishing device containing microcapsules equipped with fire extinguishing agent activated at a certain temperature. It's an innovative and new solution specifically designed to extinguish fire in IP20 and higher-level panels and electrical installations with a capacity of up to 2,000 litres. FIPRON ™ cord works as an intelligent and autonomous fire extinguishing device that activates at 120 C temperature by releasing a extinguishing agent from the capsules, resulting in the extinguishing of the fire. The products are well flexible and easily installed in limited-size locations. The stickers are lightweight and can be used at – 50 C to +80 C and do not contain substances that strain the ozone layer. The warranty period after installation is 5 years. Specifications: Ord 3 (product code C01100100): 1 metre of cord is intended to extinguish fires in installations of up to 100 litres capacity. Maximum recommended use in installations up to 400 L capacity. Activation temperature: 120 C operating environment humidity level up to 90% operating temperature: description of -50 C to +80 C extinguishing AGENT: 3M ™ Novec ™ 1230 FIRE FIGHTING FLUID  

FIPRON cord 2 fire-extinguishing cord

292.80
FIPRON ™ ord 2 is a string type stand-alone fire extinguishing device containing microcapsules equipped with fire extinguishing agent activated at a certain temperature. It's an innovative and new solution specifically designed to extinguish fire in IP20 and higher-level panels and electrical installations with a capacity of up to 2,000 litres. FIPRON ™ cord works as an intelligent and autonomous fire extinguishing device that activates at 120 C temperature by releasing a extinguishing agent from the capsules, resulting in the extinguishing of the fire. The products are well flexible and easily installed in limited-size locations. The stickers are lightweight and can be used at – 50 C to +80 C and do not contain substances that strain the ozone layer. The warranty period after installation is 5 years. Specifications: Ord 2 (product code C01100100): 1 metre of cord is intended to extinguish fires in installations of up to 100 litres capacity. Maximum recommended use in installations up to 400 L capacity. Activation temperature: 120 C operating environment humidity level up to 90% operating temperature: description of -50 C to +80 C extinguishing AGENT: 3M ™ Novec ™ 1230 FIRE FIGHTING FLUID  

FIPRON cord 1 fire-extinguishing cord

201.30
FIPRON ™ ord 1 is a string type stand-alone fire extinguishing device containing microcapsules equipped with fire extinguishing agent activated at a certain temperature. It's an innovative and new solution specifically designed to extinguish fire in IP20 and higher-level panels and electrical installations with a capacity of up to 2,000 litres. FIPRON ™ cord works as an intelligent and autonomous fire extinguishing device that activates at 120 C temperature by releasing a extinguishing agent from the capsules, resulting in the extinguishing of the fire. The products are well flexible and easily installed in limited-size locations. The stickers are lightweight and can be used at – 50 C to +80 C and do not contain substances that strain the ozone layer. The warranty period after installation is 5 years. Specifications: Ord 1 (product code C01100100): 1 metre of cord is intended to extinguish fires in installations of up to 100 litres capacity. Maximum recommended use in installations up to 400 L capacity. Activation temperature: 120 C operating environment humidity level up to 90% operating temperature: description of -50 C to +80 C extinguishing AGENT: 3M ™ Novec ™ 1230 FIRE FIGHTING FLUID  

FIPRON cord MS fire-fighting cord

164.70
FIPRON ™ ord MS is a string type stand-alone fire extinguishing device containing microcapsules equipped with fire extinguishing agent activated at a certain temperature. It's an innovative and new solution specifically designed to extinguish fire in IP20 and higher-level panels and electrical installations with a capacity of up to 2,000 litres. FIPRON ™ cord works as an intelligent and autonomous fire extinguishing device that activates at 120 C temperature by releasing a extinguishing agent from the capsules, resulting in the extinguishing of the fire. The products are well flexible and easily installed in limited-size locations. The stickers are lightweight and can be used at – 50 C to +80 C and do not contain substances that strain the ozone layer. The warranty period after installation is 5 years. Specifications: Ord MS (product code CMS10050): 1 metre of cord is intended to extinguish fires in installations up to 50 L capacity. Maximum recommended use for installation up to 200 L capacity. Activation temperature: 120 C operating environment humidity level up to 90% operating temperature: description of -50 C to +80 C extinguishing AGENT: 3M ™ Novec ™ 1230 FIRE FIGHTING FLUID  

ISO 9001/14001 audit

100.00
In simplification, the audit of ISO 9001 and 14001 can refer to activities in three main areas: responsibility, governance and action.
  • Liability audit assess compliance with applicable laws and regulations.
  • Operational audit focuses on issues such as waste management and energy consumption.
  • Management audit compares the results with the objectives of the organisation's environmental management system ISO 14001.
  • Financial audits may assess the avoidance of associated costs, energy savings and fines for environmental infringements.
An audit by a consultant or auditor may evaluate the entire quality management or environmental management system or its specific components. The overall audit shall assess the environmental impacts of management, production processes, use and waste management. The post audit report provides guidance for continuous performance improvement. The price of the service includes 1 hour of specialist work during which further organisation-based activity is mapped and valued according to the actual work volume. 

SHEQ Representative

100.00
SHEQ representative The (Safety, Health, Environment, quality) service is designed to support a team of a company or organization that must have at least one of the following:
  • working environment specialist;
  • work Environment Commissioner;
  • Member of the working environment Council.
  • quality specialist;
  • fire safety specialist;
  • risk manager;
  • safety driver, etc.
Our external specialist supports and represents the customer to the extent and under the conditions agreed in advance. With a cooperation agreement of at least 12 months, it is possible to assign the representative a job title which is compatible with the client's structure and the right of representation of the supervisory board (Tööinspektsioon, Päästeamet, etc.). The customer pays for the consulting service based on the current hourly rate. The price of the service includes 1 hour of specialist work during which further organisation-based activity is mapped and valued according to the actual work volume. 

Occupational risk assessment

550.00
Submission of risk assessment is mandatory for employers and must be provided The self-service environment of the Labour Inspectorate. In the course of the risk assessment, we determine the risk factors of the employer's working environment, assess the size of the risk, or risks, and determine measures to reduce the risks. If necessary, the parameters of the hazard factors (e.g. noise, vibration, chemical composition of air, etc.) shall be measured. Activities related to risk analysis include, for example:
  • familiarizing yourself with existing work processes and manuals;
  • chat with management and employees
  • visiting the working environment;
  • drawing up the necessary questionnaires;
  • drawing up a summary;
  • drawing up a risk reduction action plan.
  • presentation of risk analysis.
In case of questions and problems, our specialists and experts will provide advice.  The price of the service includes 16 hours of specialist work during which further organisation-based activity is mapped and valued according to the additional work volume. In general, no additional fees will be added to most small businesses.

Risk analysis audit

150.00
The purpose of the risk analysis audit is to identify and evaluate changes in the risks in the working environment. The audit shall be carried out in cooperation with the client and only the parties necessary for carrying out the audit shall be involved. We will carry out the audit in stages:
  • access to risk analysis;
  • gathering information on the working environment, the working process and employees;
  • identification of occupational hazards;
  • risk assessment relating to risk factors;
  • assessment of activities to eliminate or reduce risk;
  • documentation of risk assessment.
It is reasonable to carry out a risk analysis audit whenever processes, activities or sites change within an organisation. The external auditor is independent and his involvement provides greater added value to the organisation's sector-specific team. In case of questions and problems, our specialists and experts will provide advice.  The price of the service includes 1 hour of specialist work during which further activity is mapped and valued according to the actual work volume.

Ventilation maintenance

90.00
Cleaning of ventilation systems is mandatory and according to EVS 812-2:2014 fire safety of construction works, the frequency of cleaning must be at least once a year, with maintenance intervals not exceeding 365 days. Ventilation ducts for professional kitchens must be cleaned according to the intensity of use:
  • at least once a quarter if the equipment is used 12 h/day –16 h/day;
  • at least once a half-yearly period if the equipment is used 6 h/day –12 h/day;
  • at least once a year if the equipment is used 2 h/day -6 h/day.
The service includes one system fire safety inspection and 1 h cleaning in the Harju County area. Elsewhere in the area or for more ventilation systems, ask for a personal offer.

Chimney sweeper service

90.00
Regular chimney sweeping helps prevent a number of dangerous situations. Soot and pitch build up in the chimney during the heating process and this can cause chimney fires over time. An uncleaned chimney is a high fire risk that could threaten the safety of the entire building and its residents. Maintenance of heating systems ensures that they operate efficiently. Once the chimney and heaters are clean, the heating system can pull properly and generate heat in time. The chimney sweeper service includes fire safety inspection and cleaning of one heating system in the Tallinn area. Elsewhere in the region or for more heating systems, ask for a personal offer. The chimney sweep must be carried out by a qualified specialist who holds the relevant professional certificate. Chimney sweeps shall have at least level 4 or level 5 professional qualifications.