Occupational risk assessment

550.00
Submission of risk assessment is mandatory for employers and must be provided The self-service environment of the Labour Inspectorate. In the course of the risk assessment, we determine the risk factors of the employer's working environment, assess the size of the risk, or risks, and determine measures to reduce the risks. If necessary, the parameters of the hazard factors (e.g. noise, vibration, chemical composition of air, etc.) shall be measured. Activities related to risk analysis include, for example:
  • familiarizing yourself with existing work processes and manuals;
  • chat with management and employees
  • visiting the working environment;
  • drawing up the necessary questionnaires;
  • drawing up a summary;
  • drawing up a risk reduction action plan.
  • presentation of risk analysis.
In case of questions and problems, our specialists and experts will provide advice.  The price of the service includes 16 hours of specialist work during which further organisation-based activity is mapped and valued according to the additional work volume. In general, no additional fees will be added to most small businesses.

Risk analysis audit

150.00
The purpose of the risk analysis audit is to identify and evaluate changes in the risks in the working environment. The audit shall be carried out in cooperation with the client and only the parties necessary for carrying out the audit shall be involved. We will carry out the audit in stages:
  • access to risk analysis;
  • gathering information on the working environment, the working process and employees;
  • identification of occupational hazards;
  • risk assessment relating to risk factors;
  • assessment of activities to eliminate or reduce risk;
  • documentation of risk assessment.
It is reasonable to carry out a risk analysis audit whenever processes, activities or sites change within an organisation. The external auditor is independent and his involvement provides greater added value to the organisation's sector-specific team. In case of questions and problems, our specialists and experts will provide advice.  The price of the service includes 1 hour of specialist work during which further activity is mapped and valued according to the actual work volume.

Ventilation maintenance

90.00
Cleaning of ventilation systems is mandatory and according to EVS 812-2:2014 fire safety of construction works, the frequency of cleaning must be at least once a year, with maintenance intervals not exceeding 365 days. Ventilation ducts for professional kitchens must be cleaned according to the intensity of use:
  • at least once a quarter if the equipment is used 12 h/day –16 h/day;
  • at least once a half-yearly period if the equipment is used 6 h/day –12 h/day;
  • at least once a year if the equipment is used 2 h/day -6 h/day.
The service includes one system fire safety inspection and 1 h cleaning in the Harju County area. Elsewhere in the area or for more ventilation systems, ask for a personal offer.

Chimney sweeper service

90.00
Regular chimney sweeping helps prevent a number of dangerous situations. Soot and pitch build up in the chimney during the heating process and this can cause chimney fires over time. An uncleaned chimney is a high fire risk that could threaten the safety of the entire building and its residents. Maintenance of heating systems ensures that they operate efficiently. Once the chimney and heaters are clean, the heating system can pull properly and generate heat in time. The chimney sweeper service includes fire safety inspection and cleaning of one heating system in the Tallinn area. Elsewhere in the region or for more heating systems, ask for a personal offer. The chimney sweep must be carried out by a qualified specialist who holds the relevant professional certificate. Chimney sweeps shall have at least level 4 or level 5 professional qualifications.

Inspection and maintenance of fire hose system

15.00
The fire hose system is an efficient extinguishing tool that allows rapid relief in case of fire. The possessor of the object shall ensure the observation, inspection and maintenance of the system and maintain documentation of the operations. The operational readiness of the fire hose system and measurement of water supply efficiency shall be performed once a year.  The flameguard range includes all the components needed to complete the system or as spare parts: hose cupboards, tumble hose cupboards, hoses, couplings, valves, shut-off hoses, markings, instructions, etc.   In case of questions and problems, our specialists and experts will provide advice.  The price of the service includes 1 product check and the need for more products check is mapped and priced according to the actual work volume.   

Inspection and maintenance of fire extinguishers

Original price was: 8.00€.Current price is: 7.00€.
Fire extinguisher inspection is part of the maintenance activities of fire safety installations and can only be ensured if the person carrying out the works has been provided with appropriate training and the relevant equipment, machines, tools and instructions therefor. The person performing the inspection and maintenance of fire extinguishers shall follow the maintenance instructions of the manufacturer, standard EVS 933:2017 of the Republic of Estonia and the corresponding regulation of the Minister of the Interior.  In case of questions and problems, our specialists and experts will provide advice.  The price of the service includes 1 product check and the need for more products check is mapped and priced according to the actual work volume.   

Fire protection works

69.00
The purpose of fire protection and protection works is to ensure the resistance of fire protection structures to heat and insulation capacity to combustion gases and smoke. We carry out fire protection works across Estonia, offering fire-resistant and certified solutions for complex structures, including fire protection works for heritage-protected buildings. In the course of the works, we assess the load bearing structures of the construction work and inspect fire compartments to ensure their uniformity and integrity. In addition, we carry out construction work if deficiencies become evident in the course of fire safety audit which hinder obtaining a permit for use of the building. In case of questions and problems, our specialists and experts will provide advice.  The price of the service includes 1 hour of project consultation and further activity is mapped and priced according to actual material and work volume.

ATS system maintenance

69.00
An automatic fire alarm system is a system that automatically signals an emerging fire hazard. Such signalling shall inform of the danger with a view to protecting human life and preventing serious damage to property. To ensure the smooth operation of the system, it must be maintained regularly. The maintenance conditions of the fire alarm system are regulated by the laws of the Republic of Estonia and are mandatory for all ATS owners. Ensure your safety and order maintenance of the fire alarm system today!  In case of questions and problems, our specialists and experts will provide advice.  The price of the service includes 1 hour of maintenance and further activity is mapped and priced according to the actual work volume.   

Intuselector fire protection work app

App info  The Intuselector is a user-friendly and easy-to-use app for fireproofing that is ideal for the user of a computer, iOS, and Android smart device. This intelligent tool finds solutions based on the fireproof element or product you choose, and gives the DIY self-builder the opportunity to learn how to use the products. Intuselector is a user-friendly application developed to provide a simple and simple way to find and choose the perfect solution for passive fire protection of sanitary, electric and ventilation probe seals and expansion joints. You can download a completed technical implementation drawing from the app.   Developer information  INTUSEAL SP Z O  dev@intuseal.com  1 ul. Kineskopowa 05-500 Piaseczno Poland  +48 691 788 998     

Lithium battery fire and explosion resistant charging cabinet CEMO 8/10 feet, 1 phase-in

4,022.00
Battery charging cabinet 8/10, LockEx with locking system. With support legs, 1 phase connection 3500W, 16A (2 x 6 connectors) and ventilation. The cabinet is equipped with a smoke detector and a power shut-off system. Technical data: Width: 80 cm Height: 111 cm depth: 66 cm weight: 135 kg certificates from the TÜV NORD Group using the latest testing program M02/22, which includes real battery fire tests and generated gas explosions. MPA-tested fire resistance for more than 60 minutes outside the interior according to EN 1363-1 standard. Made from non-flammable and refractory components.

Lithium battery fire and explosion resistant charging cabinet CEMO 8/5 feet, 1 phase-in

3,387.00
Battery charging cabinet 8/5, LockEx with locking system. With support legs, 1 phase connection 3500W, 16A (2 x 6 connectors) and ventilation. The cabinet is equipped with a smoke detector and a power shut-off system. Specifications: Width: 80 cm Height: 111 cm depth: 66 cm weight: 135 kg certificates from the TÜV NORD Group using the latest testing program M02/22, which includes real battery fire tests and generated gas explosions. MPA-tested fire resistance for more than 60 minutes outside the interior according to EN 1363-1 standard. Made from non-flammable and refractory components.

Lithium battery fire and explosion resistant charging cabinet CEMO 8/5 feet-less, 1 phase-in

3,281.00
Battery charging cabinet 8/5, LockEx with locking system. Without support legs, with 1 phase connection 3500W, 16A (6 plugs) and ventilation. The cabinet is equipped with a smoke detector and a power shut-off system. Specifications: Width: 80 cm Height: 52 cm depth: 66 cm weight: 80 kg certificates from the TÜV NORD Group using the latest testing program M02/22, which includes real battery fire tests and generated gas explosions. MPA-tested fire resistance for more than 60 minutes outside the interior according to EN 1363-1 standard. Made from non-flammable and refractory components.